View Full equipment list
Sr.No. | Description |
---|---|
1 | DSO:100 MHz, 2 Analog Channels Digital Storage Oscilloscope |
2 | DSO:Oscilloscope 300MHz, multimeter, analyser and recorder modes, with the recorded files directly viewable on the oscilloscope. Safety: channels genuinely isolated from one another and from the earth, 600 V CAT III |
3 | Clamp: True RMS 1000A AC/DC Clamp Meter |
4 | DMM: True RMS 50000 count handheld DMM with freq counter and squarewave output |
5 | DMM with USB : True RMS 10000 count handheld DMM with data-logging |
6 | DMM: True RMS 6000 count handheld DMM with non-contact voltage detector |
7 | LCR: Meter, handheld, 20000 count, dual display 100Hz/120Hz/1KHz/10KHz/100KHZ |
8 | AFG: 60MHz,2-channel,Arbitary Function |
9 | Soldering Station: 80 W, 230 V |
10 | MSO: Mixed Signal Oscilloscope: 500 MHz, 8 Analog Plus 16 Digital Channels with all accessories |
11 | MSO ADD ON: 70 MHz, 7 kV high-voltage differential probe |
12 | MSO ADD ON: 800 MHz 10:1 Differential Probe with AutoProbe |
13 | MSO ADD ON: 100 MHz/15A AC/DC Current Probe |
14 | MSO ADD ON : Power Rail Probe |
15 | MSO ADD ON :39 KV Probe DC |
16 | LCR Meter : 20Hz to 2MHz, LCR components,Material measurement, Semiconductors. |
17 | LCR Meter ADD ON : SMD Test Fixture |
18 | LCR Meter ADD ON : Large Kelvin Clip Lead |
19 | LCR Meter ADD ON : Test fixture for axial and radial leaded components |
20 | High-Definition Oscilloscope: 6 GHz, 4 Analog Plus 16 Digital Channels + ADD Ons as follows |
21 | USB differential scope - 4 channel ( 50 MHz) |
22 | USB Power scope - 4 Channel ( 50 MHz) |
23 | Battery operated automotive Scope Kit |
24 | USB MSO for automotive scope ( 1 GHz) |
25 | Multi channel Signal analysis and real time demodulation software ( GNSS + DVBS2 + LMR = YAESU, MOTOBRO , AM , FM , ASK ,PSK etc.) |
26 | Ultra Wide Band antenna set |
27 | Electronic Load: 300W, 24A / 500V |
28 | Electronic Load: Configurable module mainframe ( 4 Slots ) |
29 | Electronic Load ADD ON - USB Card |
30 | Programmable DC Power Supply 0-60 Volts, 0 to 35 Amp, 2100 Watt, GPIB |
31 | Programmable AC Power Source |
32 | DC Power Supply Set |
33 | DC Power Supply : 80V,510A,15000W,240VAC, Autoranging power supply |
34 | Handheld Microwave Analyzer, 44 GHz |
35 | 8X8 RF MIMO system |
36 | 18 GHz Spectrum Analyser Benchtop |
37 | 4 Channel RF wireless protocol Analyser + generator |
38 | Vector signal generator + spectrum analyser (6 GHz) |
39 | RF MIMO signal analysis software |
40 | Precision Source Measurement Unit ( 2 Channel ) |
41 | Gigabit ethernet Software defined radio |
42 | ECU Diagnosos Unit |
43 | ECU Diagnosos Unit ADD ON : ECU Diagnosos Software |
44 | Engine Analyzer Kit |
45 | Battery Testing Unit |
46 | Engine Analyzer Kit ADD ON - Test Adaptors |
47 | Data Acquisition System |
48 | Data Acquisition System ADD ON - Transit Case |
49 | Data Acquisition System ADD ON - 20 Channel Multiplexer (2/4-wire) Module |
50 | Regenerative Power Supply |
51 | Automatic LED Drive Power Analyzer |
52 | IoT Wireless Communication Course Kit |
53 | IoT Sensors and Power Management Course Kit |
54 | Safety Analyser |
55 | IR Rework System with camera |
56 | Rework Station |
57 | Preheating Plate 24V, 80W |
58 | Solder Dispenser |
59 | Solder Station |
60 | Fume extractor ( 4 Channel ) |
61 | IR Rework System with camera ADD ON - Tip Set |
62 | EMI Receiver |
63 | RF Connector sets |
64 | RF Attenuator Sets |
65 | RF Cable Sets |
66 | RF Amplifier Sets |
67 | RF Antenna Sets |
68 | Electrical Probes and Aceessories of various instruments |
1. N2893A AC/DC Current Probe, 100 MHz, 15A
- Wide bandwidth: DC to 100 MHz
- High S/N ratio, low current measurement capability
- 15A peak, 15ADC, 10Arms continuous, 30A peak non-continuous
- Easy protect function at excessive input
- Auto demagnetization (degauss) and calibration removes any residual magnetism and unwanted DC offset in the probe
- Compatible with high impedance Auto Probe interface
- For use with 80000/90000 Series, use N278xA current probe with N2779A power supply and E2697A high impedance adapter
- For use with 90000 X-Series, use the N5449A high impedance probe adapter
2. N2819A DIFFERENTIAL PROBE 800MHZ WITH AUTO PROBE:
- Wide dynamic range for various applications: ±15V differential, ±30V common mode
- High input resistance and low input capacitance for low probe loading: 200 kΩ//1pF between inputs
- Ideal for high-speed power measurements, digital differential buses, and vehicle serial buses (CAN, LIN, FlexRay)
- The N2819A differential probes offer 10:1 attenuation setting, allowing them to be used for a broad range of applications.
- The differential probes have an input resistance of 200 kΩ and low input capacitance of 1 pF to minimize circuit loading.
3. N2891A DIFFERENTIAL PROBE 70MHZ:
- 70 MHz bandwidth
- User-selectable attenuation settings of 100:1 or 1000:1
- Rated to measure differential and common mode voltage up to ±7000 V at 1000:1 mode
- Powered by included 4x AA batteries or USB host port of scope or PC
- Obtain floating signal measurements of up to ±7000 V of differential and common mode voltage
4. DP0001A 400 MHz High Voltage Differential Probe:
- 400 MHz bandwidth
- 2,000 Vrms mains isolated, 6,000 V transient overvoltage
- Attenuation ratios: 50:1, 100:1, 250:1 or 500:1, auto-switchable on Infiniium scope
- Differential input impedance: 10 MΩ || 2pF
- AutoProbe interface, 50 Ω input
- The probe is compatible with InfiniiVision 3000TX, 4000X, 6000X and Infiniium S, 9000A, 90000X, V, Z, UXR <=33GHz (with N5442A adapter).
5. N2779A Power Supply for N2780-83A / B Current Probe:
- The Keysight N2779A power supply provides clean dc power for the N2780-83A / B current probe.
- Use the three 12-V outputs to connect up to three N2780-83A / B current probes, enabling you to make effective three-phase power measurements.
- This power supply is a universal AC input power supply covering 100 to 240 VAC, 50 / 60 Hz AC input.
- Make effective three-phase power measurements with three 12-V outputs
- Includes universal AC input power supply, covering 100 to 240 VAC, 50 / 60 Hz AC input
6. N7020A Power Rail Probe, 2 GHz:
- Low noise: 1:1 attenuation ratio probe adds only 10% to the baseline noise of the oscilloscope it is attached.
- Large offset range: Has a large +/-24 V offset range, enabling users to set their oscilloscope at maximum sensitivity and have the signal centred on the screen
- Low DC loading: 50 kΩ DC input impedance will not significantly load DC power rails
- Large active signal range: Has a +/-850 mV active signal range in addition to its large offset range so users can measure large transitions of their power rails
- High bandwidth: 2-GHz bandwidth makes it very useful for finding high-speed transients that can have detrimental effects on clocks and digital data
7. E2646B SQUIDD TEST FIXTURE FOR USB 2.0 TESTING:
- Compatible Oscilloscopes: Infiniium 8000 Series, Infiniium 9000 Series, Infiniium 80000 Series, Infiniium 90000 Series
- SQuIDD (signal quality inrush, drop/droop) test fixture for: Full-speed signal quality testing, Low-speed signal quality testing, Inrush current testing.
- Host and Hub droop/drop testing (requires USB-IF approved Droop/Drop test fixture)
- Required for N5416A USB 2.0 compliance test software.
- Compatible with Infiniium 8000, 9000, 80000 and 90000 Series oscilloscopes.
8. E2678B INFINIMAX SINGLE ENDED/ DIFFERENTIAL SOCKETED PROBE:
- E2678A differential socket probe head can be used to measure either differential or single-ended signals via a plug-on socket connection.
- InfiniiMax single-ended/differential socketed probe head and accessories. Includes 48 full bandwidth damping resistors, 6 damped wire accessories, 4 square pin sockets and socket heatshrink
9. 1131B PROBE AMPLIFIER INFINIIMAX 3.5 GHZ:
- Test setup wizard guides you through test selection, configuration, connection, execution, and results reporting
- Measurement connection setups are displayed
- Oscilloscope setup is automatically configured for each test
- USB-IF recognized for use in USB 2.0 compliance testing
- MATLAB scripts used are from the USB-IF organization
10. D9010JITA EZJIT COMPLETE-JITTER, VERTICAL, PHASE NOISE ANALYSIS SOFTWARE:
- With the faster edge speeds and shrinking data valid windows in today’s high-speed digital designs, insight into the causes of signal jitter is critical for ensuring the reliability of your design.
- EZJIT Complete software for Infiniium oscilloscopes provides the advanced decomposition, analysis, and views of jitter necessary for fast and accurate insight into your signal
11. 9010USBC USB 2.0 Tx COMPLIANCE SOFTWARE:
- Test setup wizard guides you through test selection, configuration, connection, execution, and results reporting
- Test results report documents test configuration, measurements made, pass/fail status, margin analysis, and waveforms.
- USB-IF recognized for use in USB 2.0 compliance testing
- MATLAB scripts used are from the USB-IF organization
12. MXR604A INFFINIUM MXR SERIES REAL TIME OSCILLOSCOPE 6GHZ 16GSAs/4CHN2783B AC / DC Current Probe, 100:
- 6 GHz on all 4 analog channels
- Faster test speeds than ever before with ASICs from the Infiniium UXR-Series
- Accurate measurements with ENOB up to 9.0, noise as low as 43 µV
- Maximum memory is a flexible 1.6 G points
- Capabilities are extended with 8-in-1 instrument integration
- Upgradeable in every possible way — including bandwidth and channel upgrades
13. D9011BDLP Basic Infiniium Protocol Trigger/Decode Bundle for Infiniium Oscilloscopes:
- Get your low speed serial debug done faster and simpler by using this package, which combines 5 of the most popular trigger/decode packages into one
- Set up your scope to show specific protocol decoding in less than 30 seconds with an auto setup feature
- Get access to a rich set of integrated protocol-level triggers – see datasheet for a complete list
- Save time and eliminate errors by viewing packets at the protocol level
- Use time-correlated views to quickly troubleshoot serial protocol problems back to their timing or signal integrity root cause
14. Real time Oscilloscope: 500 MHz, 8 Channels:
- Option to integrate up to 8 instruments in one, hardware accelerated plotting, and fully upgradeable to 6 GHz.
- 500 MHz on all 8 analog channels
- Faster test speeds than ever before with ASICs from the Infinium UXR-Series
- Accurate measurements with ENOB up to 9.0, noise as low as 43 µV
15. N2783B AC / DC Current Probe, 100 MHz, 30 Arms:
- The N2783B current probe is an accurate and reliable solution for measuring AC and DC currents.
- Use with any Keysight oscilloscope with high impedance BNC input: 1000, 2000 X-, 3000 X-, 4000 X-, 5000, 6000, 7000, 8000, and 9000 Series (Use E2697A with 90000A Series and N5449A with 90000 X-Series)
- Achieve flat bandwidth – DC to 100 MHz, maximum current 30 Arms
- Prevents probe damage with overload protect function
- Connect up to three N278xBs to a single power supply with external power supply N2779A
16. D9010PWRA Power Supply Test Software for Infiniium Oscilloscopes:
- Input, switching device, output, and frequency response analysis measurements for power supplies..
- The broad range of automated power supply characterization measurements including critical frequency response measurements such as power supply rejection ratio (PSRR) and control loop response (Bode plots).
- The Infiniium MXR-Series and EXR-Series oscilloscopes also support multi-channel waveform mask testing for detailed analysis of supply system turn-on/turn-off testing of up to 8 power supply lines.
17. Railway Capacitor Testing
Capacitor Discharge Testing is for Railways 30 KV A/c and D/c Voltage is applied to capacitor and it is a destructive testing then if the capacitor bursts then the test fails and if the it doesn’t burst then the test is successful .